| Working Pressure: | Air (pneumatic) up to 1,500 psi (103 bar) Hydraulic oil or lubricated water, up to 3,000 psi (206 bar) |
| Pressure Drop: | 9 psi at 2.5 gpm 32 psi at 4 gpm |
| (For more detailed pressure drop and flow capacity information, see valve supplemental guide) | |
| Max. Fluid Velocity: | 20ft/sec (6.1 m/sec) |
| Cv Factor: | 0.7 |
| Min. Flow Diameter: | 7/32 in. (5.6mm) |
| Back Pressure: | Must not exceed 250 psi (17.2 bar) at return port for satisfactory operation |
| Proof Pressure: | 1-1/2 times working pressure except at return port |
| Burst Pressure: | 2-1/2 times working pressure except at return port (3000 psi [206 bar]) |
| Media Temperature Range: | -40° to +250°F (-40° to +121°C) |
| Electrical Data: Solenoid Voltage: Current - Inrush: Current - Holding: | 115V AC at 60 Hz (Alternative AC & DC voltages are available). 16.8 amps 1.52 amps |
| Voltage Tolerance: | ±10% of rated voltage |
| Solenoid Rating: | Continuous duty |
| Material of Construction: Slide: Body & Pressure Fittings: Pressure Seals: Standard O-Ring: Back-up Rings: | 400 series stainless steel Bronze Stainless Steel Buna N Tefl on® |
| Shipping Weight: | 11.5 Lbs. / Explosion-Proof 20 Lbs. |