| Accuracy: | ± 2% of the adjustable range |
| Switch: Type: Rating: | Single pole double throw (SPDT) snap action; single circuit Class H limit switch: 10 amps @ 125/250 VAC; 3 amps @ 480 VAC; 0.5 amps @ 24 VDC (standard). |
| Wetted Parts: Process Fitting: Seals & Diaphragms: Enclosure: | Anodized aluminum (standard) Buna-N (standard) Anodized aluminum (housed models) |
| Electrical Connection: Stripped Models: Housed models: | Screw terminals Screw terminals via 1/2" NPT female conduit connection |
| Enclosure Ratings: Stripped models: Housed models: | NEMA 1 NEMA 4 & IP65 |
| Pressure Connection: Stripped models: Housed models: | 1/2" NPT external with 1/8" NPT internal 1/4" NPT female |
| Approvals: UL: CSA: PED (European): | Stripped models: UL recognized component (UR) Housed models: UL listed. File No. E42816 All models and modifications shown are CSA listed under Guide 380-W-1.16, Class 3231, File LR22355 Compliant to PED 97/23/EC |
| Temperature Range: Operating: | -20° to +165°F (-29° to +74°C) |
| Adjustment Setpoint: Positive Pressure: Vacuum: Adjustable Deadband (Optional): | Turn self locking adjustment nut clockwise to increase setpoint; counterclockwise to decrease setpoint. Turn self locking adjustment nut counterclockwise to increase setpoint, clockwise to decrease setpoint (towards 30?? Hg). Turn small self locking adjustment nut on limit switch counterclockwise to increase differential. As the differential is increased, the setpoint is also increased. Balance one adjustment against the other to obtain the desired setpoint. |
| Options: | -Plastic cover (stripped models only) -NEMA 4X enclosure (housed models only) -Cleaned for oxygen service -Manual reset -Adjustable deadband |
| Shipping Weight: Housed models: Stripped models: | 1.5 lbs. approx. 0.75 lbs. approx. |